Specification Details For ANTSPACE HK3 V6

Product Overview  
Model ANTSPACE HK3 V6
Dimensions (L*W*H) (mm) 6058*2438*2896
Miner Capacity 210 units -S19 Hyd. & S21 Hyd. Series miner
Container Certification China Classification Society Certification
Safety Certification

NFPA 79:2021
UL 508A:2018 R8.21
CSA C22.2 No. 14-18
ANSI/ISO 12100:2012
IEC 60204 Ed 5.1 2009

Operating Power(kW) 1047~1050
PUE(Power Usage Effectiveness) 1.022(Excluding cooling tower)/1.032(Including cooling tower)
Input Voltage and Frequency

400V±5% 50/60Hz

Detailed Characteristics  
Shipping Weight(T) 8
Operating Weight (T) 12
Main Switch of Power Distribution Cabinets(A) 1200*2
Rated Current(A) A:952; B:866
Rated Current per Miner(A) 10
Inlet Cable The inlet cables can withstand high-voltage of above 600V, with the following requirements:
L1 single core cable 600kcMil(300mm²)x4
L2 single core cable 600kcMil(300mm²)x4
L3 single core cable 600kcMil(300mm²)x4
N Single-core cable 600kcMil(300mm²)x4
PE single-core cable 500kcMil(240mm²)x2
Connection Interface(Cooling Tower) DN100(ISO2852 PN16)
Connection Interface(Plate Heat Exchage Interface) DN100(GB/T 9122-2010 PN16 DN100)
Flow Rate(m³/h) >85
Quantity of ANTSPACE powered by one 2500kVA Transformer 2

Specification Details For Dry-Wet Tower

Product Overview  
Type Dry-Wet Tower Container Type 
Dimensions(L*W*H)(mm) 6058*2438*2896
Heat Dissipation Capacity(kW) 1000
Outlet Temperature @ 28℃ Wet Bulb Temperature 35℃
Container Certification China Classification Society Certification
Safety Certification

NFPA 79:2021
UL 508A:2018 R8.21
CSA C22.2 No. 14-18
ANSI/ISO 12100:2012
IEC 60204 Ed 5.1 2009

Operating Power(kW) 14~28
Motor Rated Voltage and Frequency

400V±5% 50/60Hz

Detailed Characteristics  
Shipping Weight(T) 7
Operating Weight(T) 13
Connection Interface DN125(ISO2852 PN16)
Water Resupply Pipe Interface DN40(Internal thread)
Drain Pipe Interface DN65(Internal thread)
Noise Level @25℃, 15m 70dBA
Water Consumption(m³/h) 0.7~1.3m³/h

 

Specification Details For Dry Tower

Product Overview  
Type Dry Tower Container Type
Number 2
Dimensions(L*W*H)(mm) 6058*2438*2896
Outlet Temperature @ 30℃ ambient temperature 35℃ (Outlet temp 5℃ above ambient temp)
Container Certification China Classification Society Certification
Operating Power(kW)

20~32

Motor Rated Voltage and Frequency 400V±5% 50/60Hz
Detailed Characteristics  
Shipping Weight(T) 6
Operating Weight(T) 8
Connection Interface DN100(ISO2852 PN16)
Water Resupply Pipe Interface DN10(Tapered tube)
Noise Level @25℃, 15m 70dBA
Pipe materials 304 stainless steel

Specification Details For Plate Heat Exchanger

Product Overview  
Type Plate Heat Exchanger 
Dimensions(L*W*H)(mm) 775*480*1069
Material TI
Detailed Characteristics  
Shipping Weight(KG) 379
Operating Weight(KG) 461
Connection Interface DN100(GB/T 9122-2010 PN16 DN100)
External circulation supply liquid temperature (℃) 0~30
External circulation flow rate (m³/h) 33~110
Internal circulation flow rate (m³/h) 100

 

| Points For Attention

1 The cooling tower must be placed on a flat ground with a level of ±1 degree.
2 The surface ground needs to be hardened and aimed to hold the ANTSPACE to be stable to withstand the load of at least 25 tons. 
3 The customers need to prepare a 20-ton crane to load and unload ANTSPACE and Cooling-tower.
4 Stairs, walkway boards, transformers, cables, bridges, cable distribution boxes, and other external facilities are included in ANTSPACE products.
5 If you plan to store ANTSPACE units vertically on top of one another, please advise the MINERS MARKET team regarding the preferred opening direction for the door facing the air inlet of your ANTSAPCE unit. The door opens to the left by default.
6

Leave at least 2 meters of air inlet space around the cooling tower.

7 Operating elevation: lower than 2000 meters. If the height is more significant than 1000 meters and a 2500kVA transformer, the number of ANTSAPCE units installed in one ANTSPACE unit must be decreased by around 1%.
8 Environmental requirements: 
Temperature: -25°C~40°C; Humidity 10%RH~90%RH; 
The ambient temperature requirement in high-humidity areas is not higher than 40°C. When the ambient temperature is lower than 0°C, the inlet and outlet shutters need to be closed, and the interior of the mining machine can only be started when it is heated to above 20°C.
9 The ambient temperature of the ANTSPACE does not represent the ambient temperature of the mining machine.

 

 


We accept payments in cryptocurrencies such as Bitcoin, Ethereum, and USDT. For a complete list of payment options, visit our Payment Methods page.

Worldwide Delivery: We deliver globally through DHL and UPS.

Secure Delivery: Signature is required upon delivery for added security.

All orders are processed within 48-72 Hours after payment confirmation. We ensure efficient handling to get your equipment to you as quickly as possible.

View full details